{"product_id":"mvg-eme-guard-xs","title":"MVG 5G Radiation Meter EME Guard XS 1MHz–40GHz","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003ch2\u003eProtect from EMF Exposure near Antennas with the EME Guard XS 40 GHz 5G Radiation Detector\u003c\/h2\u003e\n\u003cp\u003eThe EME Guard XS 40 GHz is specifically designed for individuals working near antennas, such as installation and maintenance workers, broadcast, PMR, mobile phone operators, or regulatory body employees. As higher 5G frequencies continue to proliferate, the EME Guard XS 40 GHz provides optimal personal in-field protection from 1 MHz up to 40 GHz when installing or maintaining high-power RF sites.\u003c\/p\u003e\n\u003ch4\u003eIsotropic Tri-Axis E-field Sensors for Comprehensive EMF Monitoring\u003c\/h4\u003e\n\u003cp\u003eThis detector features isotropic tri-axis E-field sensors that continuously scan for electromagnetic radiation in all directions. It utilises a combination of LED lights and alarms to alert you when RF levels change, ensuring you stay informed and protected from potentially harmful EMF exposure.\u003c\/p\u003e\n\u003ch4\u003eAdaptable to International EMF Exposure Standards\u003c\/h4\u003e\n\u003cp\u003eYou can order your EME Guard XS 40 GHz set to any of these 4 standards: ICNIRP, FCC 96-326, Safety Code 6, and 2013\/35\/EU. The alarm threshold can be adjusted at the MVG factory upon request, allowing for customisable protection based on your needs and preferences.\u003c\/p\u003e\n\u003ch4\u003eStay Safe and Informed with the EME Guard XS 40 GHz 5G Radiation Detector\u003c\/h4\u003e\n\u003cp\u003eWith increasing concerns about the health effects of radio waves, this RF safety tool is crucial for keeping those working close to emitting antennas (broadcast, base stations, radars, etc.) safer. It is easy to use, continuously scanning electromagnetic waves and alerting the user when acceptable limits have been exceeded. The sensitivity range of 5 V\/m to 350 V\/m ensures accurate EMF measurement across various environments.\u003c\/p\u003e\n\u003cp\u003eDon't compromise your health and safety when working near antennas. Invest in the EME Guard XS 40 GHz 5G radiation detector today and experience unparalleled protection and peace of mind. Order now and secure your defence against EMF exposure in the era of 5G technology.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cstrong\u003e\u003c\/strong\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous monitoring of Electromagnetic Field (EMF)\u003c\/li\u003e\n\u003cli\u003eCustomisation of alarm thresholds\u003c\/li\u003e\n\u003cli\u003eEMF level indicated by a LED colour scale\u003c\/li\u003e\n\u003cli\u003eAudio and visual alarms triggered when EMF exceeds the reference level\u003c\/li\u003e\n\u003cli\u003eAccurate measurement with tri-axis sensors\u003c\/li\u003e\n\u003cli\u003eMeasurements up to 40 GHz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"feature-heading\"\u003e\u003cstrong\u003eCapabilities\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul data-v-a4c7a7c6=\"\"\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eContinuous monitoring of Electromagnetic Field levels with isotropic tri-axis E-field sensors\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eEMF Level indicated by a LED colour scale\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eAudio and visual alarms triggered when EMF exceeds the reference level\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUser Profile\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePersons working near antennas including installation and maintenance workers, broadcast, PMR and mobile phone operators or regulatory body employees\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul data-v-a4c7a7c6=\"\"\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eEME Guard XS 40 GHz\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eMVG Case\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eWirst strap\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eLanyard\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eConnecting adapter\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eArmband\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003e2 x 1.5 V Size N Alkaline batteries\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eInstructions for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFrequency range: 1 MHz – 40 GHz\u003c\/li\u003e\n\u003cli\u003eUpper detection limit: 350V\/m\u003c\/li\u003e\n\u003cli\u003eLower detection limit: 5 V\/m\u003c\/li\u003e\n\u003cli\u003eIsotropic 3-axes probe\u003c\/li\u003e\n\u003cli\u003eFrequency response: 1-1000 MHz : +1\/+5 dB, 1-3 GHz : +\/-2.5dB dB, 3-7 GHz : +2\/+6 dB, 7-13 GHz : +6\/+11 dB, 13-27 GHz : +6\/+11 dB, 27-40 GHz : -6\/0 dB\u003c\/li\u003e\n\u003cli\u003eAxial isotropy: 100 MHz : ± 0.5 dB, 2.6 GHz : ± 1 dB, 5.5 GHz : ± 1 dB\u003c\/li\u003e\n\u003cli\u003eMeasurement period; 1 sec\u003c\/li\u003e\n\u003cli\u003eAudio alarm: Activated (from 5 V\/m to 350 V\/m)\u003c\/li\u003e\n\u003cli\u003eVisual alarm: 7 LEDs\u003c\/li\u003e\n\u003cli\u003eLow battery indicator: Orange LED\u003c\/li\u003e\n\u003cli\u003eTemperature, humidity: -10 to 50°C, 85% max. humidity\u003c\/li\u003e\n\u003cli\u003eBattery: 2x 1.5 V size N Alkaline removable batteries\u003c\/li\u003e\n\u003cli\u003eBattery life: \u0026gt; 1000 hours\u003c\/li\u003e\n\u003cli\u003eDimensions: 132.5x48.5x28.7mm\u003c\/li\u003e\n\u003cli\u003eWeight 120g with batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdiv class=\"body\"\u003e\n\u003cul data-v-a4c7a7c6=\"\"\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eICNIRP 2020\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eFCC 96-326\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003eSafety Code 6 2015\u003c\/li\u003e\n\u003cli data-v-a4c7a7c6=\"\"\u003e2013\/35\/UE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTech Sheet\u003c\/h3\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\u003c!--\n\/* Center the iframe element *\/\n  .iframe-container {\n    display: flex;\n    justify-content: center;\n    align-items: center;\n    height: 100%;\n  }\n\n  \/* Default size for the iframe *\/\n  iframe {\n    width: 640px;\n    height: 480px;\n  }\n\n  \/* Reduce the size of the iframe on mobile devices *\/\n  @media (max-width: 480px) {\n    iframe {\n      width: 100%;\n      height: 300px;\n    }\n  }\n--\u003e\u003c\/style\u003e\n\u003cdiv class=\"iframe-container\"\u003e\u003ciframe src=\"https:\/\/drive.google.com\/file\/d\/1sbicdmsfbZTzZYWtXtMarmxQlt13BexC\/preview\" allow=\"autoplay\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003ch3\u003eReturns\u003cbr\u003e\n\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e30-day returns.\u003c\/strong\u003e Let us know within 14 days of delivery that you would like to return your item, then you have a further 16 days to send it back. To start a return, email info@anti-radiation.co.uk with your order number or message our live chat.\u003c\/p\u003e\u003cp\u003eItems must be complete and in their original packaging, and are returned at your cost using a tracked service. We refund within 14 days of receiving the item back.\u003c\/p\u003e\u003cp\u003eIf a change-of-mind return has been used, or is not in its original packaging and resaleable condition, we deduct 10% to cover inspection, testing and repackaging. Nothing is deducted for items that arrive faulty, damaged or incorrect; please tell us about these within 2 days of delivery.\u003c\/p\u003e\u003ch3\u003e\u003cspan data-preserver-spaces=\"true\"\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eMVG offer a 2 year warranty on all meters. \u003c\/span\u003e\u003cspan\u003eThis warranty extends only to the purchaser and terminates upon ownership transfer. It does not extend to commercial or institutional use or installation.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThis warranty is void if the device is subject to alteration, misuse, abuse, accident, natural disaster or non-factory authorised modification or repair. This warranty is also void if the device has been operated or maintained in deviation from the published instructions. The guarantee extends only to manufacturing defects and does not cover any damages resulting from the mishandling of the product by the owner. This warranty does not cover any normal wear and tear due to usage. \u003c\/span\u003e\u003c\/p\u003e","brand":"MVG","offers":[{"title":"Default Title","offer_id":45111407411505,"sku":"EMEGUARDXS40","price":4975.0,"currency_code":"HKD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/3517\/3425\/files\/mvg-5g-radiation-meter-eme-guard-xs-1mhz-40ghz-emf-reader-7581904.jpg?v=1777516036","url":"https:\/\/anti-radiation.co.uk\/en-asia\/products\/mvg-eme-guard-xs","provider":"Anti-Radiation","version":"1.0","type":"link"}