{"product_id":"low-frequency-emf-meter-3030b","title":"ELF Tester Low Frequency EMF Meter ME3030B 16Hz-2000Hz","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan data-preserver-spaces=\"true\"\u003eMeasure Electrosmog Emissions and Dirty Electricity from Your Electrical Wiring and Appliances at Home\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe ME3030B is an affordable, high-quality ELF EMF meter designed for serious measurement of EMF\/LF electrosmog caused by household\/building power supply and appliances, high-voltage power lines, electric rail, and more. It is easy to use, sensitive, and informative, with a digital display and sounder. It is particularly well-suited to electrically hypersensitive people who wish to reduce their EMF exposure to the lowest possible levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\n\u003cspan data-preserver-spaces=\"true\"\u003eAccurate, Reliable \u003c\/span\u003e\u003cspan data-preserver-spaces=\"true\"\u003eExtremely Low Frequency EMF Meter\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe ME3030B features advanced capabilities that make it an essential tool for surveys and post-mitigation analysis. The reading shows the total pollution directly in the entity corresponding to the building biology standard values without any calculation required. The \"Geiger counter effect\" helps identify areas of increased LF stress, and the detailed measurement instruction enables the user to perform relevant measurements of EMF – even without technical expertise. The manual includes recommendations for limiting values according to the standard of building biology SBM, which allows for a meaningful assessment of the personal level of EMF pollution. With the help of this instrument, you can spot even obscured sources of LF pollution.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan data-preserver-spaces=\"true\"\u003eScientifically Accepted Measuring Methods with ELF EMF Meter\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eThe \u003cmeta charset=\"utf-8\"\u003eME3030B measures magnetic and electric fields based on scientifically accepted measuring methods and with high sensitivity (display resolution: 1 nT or 1 V\/m). The device is fully frequency compensated, meaning that not only the 50\/60 Hz mains frequency (e.g. high-voltage lines), but also the 16.7 Hz of the traction current overhead lines and natural harmonics 2 kHz are shown without distortion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eTake control of your EMF exposure with the \u003cmeta charset=\"utf-8\"\u003eME3030B. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-preserver-spaces=\"true\"\u003eOrder yours today and start measuring the electrosmog emissions from your electrical wiring and appliances. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTurn it on, set it to magnetic or electric field detection, and begin!\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 class=\"feature-heading\"\u003eFeatures\u003c\/h3\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-ruler\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eMeasures both electric and magnetic ELF fields\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-power-off\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eEasy to operate with no technical experience required\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-calculator\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eReading shows the total pollution without any calculation required\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-chart-line\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eValues are reliably displayed directly in units corresponding to the building biology standards\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-bolt\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eElectric field strength from 1 to 1999 V\/m (against ground potential), and the magnetic flux density from 1 to 1999 nT (0.01mG to 20mG)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-volume-up\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eAn acoustic signal proportional to the field strength with \"Geiger-counter-effect\" helps in identifying regions with more exposure\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"feature-heading\"\u003eBenefits\u003c\/h3\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-lightbulb\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eUnderstand your environment through dual measurements of electric and magnetic ELF fields\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-check-circle\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eEffortlessly assess EMF levels, no technical knowledge necessary\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-chart-bar\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eImmediate insights into pollution levels, no calculations required\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-shield-alt\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eMeasurements adhere to building biology standards for a safer space\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-expand-arrows-alt\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eWide measurement range detects subtle electromagnetic variations effectively\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-bullseye\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eAudible signal pinpoints high EMF areas, aiding targeted exposure reduction\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"feature-heading\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul class=\"feature-list\"\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-calculator\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eFactory calibrated ME3030B ELF EMF meter\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-battery-full\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eBattery\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-plug\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eEarthing lead\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan class=\"feature-icon\"\u003e\u003ci class=\"fas fa-book-open\"\u003e\u003c\/i\u003e\u003c\/span\u003e \u003cspan class=\"feature-text\"\u003eInstructions with building biology recommendations\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecs\u003c\/h3\u003e\n\u003ctable class=\"table table-sm table-striped table-bordered-outline\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"attr-weight\"\u003e\n\u003ctd class=\"h6\"\u003eItem weight:\u003c\/td\u003e\n\u003ctd class=\"weight-unit\" itemtype=\"https:\/\/schema.org\/QuantitativeValue\" itemscope=\"\" itemprop=\"weight\"\u003e\n\u003cspan itemprop=\"value\"\u003e0.40\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan itemprop=\"unitText\"\u003ekg\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003eFrequency range:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003e16 Hz - 2 KHz (compensated, better than -2 dB)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003eScope of delivery:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003eMeasuring device\u003cbr\u003eGrounding cable\u003cbr\u003eAlkaline manganese battery\u003cbr\u003eDetailed instruction manual with neutral background Information\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003eMeasurement range:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003eMagnetic flux density (one-dimensional): 1 - 1999 nT\u003cbr\u003eElectric field strength: 1 - 1999 V\/m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003ePrecision:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003e+\/- 2 %, +\/- 14 digits @ 50\/60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003eSensor:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003eE-field sensor for electric LF alternating fields\u003cbr\u003eH-field sensor for magnetic LF alternating fields (one-dimensional)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003eAudio analysis:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003eSound signal proportional to field strength (with \"Geiger counter effect\", switchable)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003eSignal rating:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003eRMS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003ePower supply:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003e9-volt E-block alkaline manganese battery (included), average operating time: 24 to 36 hours (depending on operating mode)\u003cbr\u003eLow-battery indicator\u003cbr\u003eAuto power-off function\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attr-custom\"\u003e\n\u003ctd class=\"h6\"\u003eWarranty:\u003c\/td\u003e\n\u003ctd class=\"attr-value\"\u003e\n\u003cp\u003e2 years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\n\u003cstrong\u003e\u003cspan color=\"#000000\"\u003e\u003cspan color=\"#0000ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\u003cstrong\u003e\u003cspan color=\"#000000\"\u003e\u003cspan color=\"#0000ff\"\u003eNOTE\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cem\u003e\u003cspan color=\"#000000\"\u003e\u003cspan color=\"#0000ff\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cem\u003e\u003cspan color=\"#000000\"\u003e\u003cspan color=\"#0000ff\"\u003eThe meters supplied by Anti-Radiation are manufacturer calibrated and are suitable for general use. Customers who wish to use our meters for certain types of formal testing, for example occupational EMF assessment to meet the needs of\u003c\/span\u003e\u003cspan color=\"#0000ff\"\u003e the UK HSE or EU EMF Directives, will most likely need to arrange for certification of individual units at an approved calibration facility. This type of certification is a common requirement  for many types of test equipment, not just EMF meters.\u003c\/span\u003e\u003c\/span\u003e\u003c\/em\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cem\u003e\u003cspan\u003eThis meter is for Power Frequency (ELF) EMFs - please see my other items for RF meters suitable for measuring EMFs from mobile phones etc.\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cspan\u003eThe measurement range of this meter may be exceeded (without damage) directly underneath 275kv and 400kv overhead lines.\u003c\/span\u003e\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eManual\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\" data-mce-style=\"text-decoration: underline;\"\u003e\u003ca title=\"Gigahertz Solutions VLF ELF manuals\" href=\"https:\/\/anti-radiation.co.uk\/pages\/gigahertz-solutions-vlf-elf-manuals\" target=\"_blank\" data-mce-href=\"https:\/\/anti-radiation.co.uk\/pages\/gigahertz-solutions-vlf-elf-manuals\"\u003eME3030B Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #000000;\" data-mce-fragment=\"1\" data-mce-style=\"color: #000000;\"\u003eReturns\u003c\/span\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003e30-day returns.\u003c\/strong\u003e Let us know within 14 days of delivery that you would like to return your item, then you have a further 16 days to send it back. To start a return, email info@anti-radiation.co.uk with your order number or message our live chat.\u003c\/p\u003e\u003cp\u003eItems must be complete and in their original packaging, and are returned at your cost using a tracked service. We refund within 14 days of receiving the item back.\u003c\/p\u003e\u003cp\u003eIf a change-of-mind return has been used, or is not in its original packaging and resaleable condition, we deduct 10% to cover inspection, testing and repackaging. Nothing is deducted for items that arrive faulty, damaged or incorrect; please tell us about these within 2 days of delivery.\u003c\/p\u003e\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWarranty \u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWe offer a 2 year manufacturer warranty on this product. This warranty extends only to the purchaser and terminates upon ownership transfer. It does not extend to commercial or institutional use or installation. This warranty is void if the device is subject to alteration, misuse, accident or repair.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eThis warranty is also void if the device has been operated or maintained in deviation from the provided instructions. The guarantee extends only to manufacturing defects and does not cover any damages resulting from the mishandling of the product. This warranty does not cover any normal wear and tear due to usage.\u003c\/span\u003e\u003c\/p\u003e","brand":"Gigahertz Solutions","offers":[{"title":"Default Title","offer_id":45102911357233,"sku":"130-544","price":179.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0749\/3517\/3425\/files\/elf-tester-low-frequency-emf-meter-me3030b-16hz-2000hz-emf-reader-gigahertz-solutions-1053353.jpg?v=1781177653","url":"https:\/\/anti-radiation.co.uk\/en-eu\/products\/low-frequency-emf-meter-3030b","provider":"Anti-Radiation","version":"1.0","type":"link"}