Salta il contenuto

VLF ELF Tester Low Frequency EMF Meter ME3840B 16Hz-100,000Hz

Prezzo originale £289.00 - Prezzo originale £289.00
Prezzo originale
£289.00
£289.00 - £289.00
Prezzo attuale £289.00

Description

User-Friendly VLF ELF EMF Meter with Professional-Grade Capabilities

The ME3840B is a cutting-edge EMF meter specifically engineered for comprehensive measurement of EMF/LF electrosmog caused by various sources, such as household and building power supplies, high-voltage power lines, electric rail systems, and more. This versatile device functions as a low-frequency EMF meter, ELF reader, and ELF meter, offering ease of use without compromising professional-grade measurement accuracy. The ME3840B is highly regarded by medical professionals and industry experts alike.

Precision Frequency Analysis EMF Meter for Reliable Dirty Electricity Detection

The standout feature of the ME3840B is its integrated Frequency Analysis capability. AC fields are characterised not only by the strength of the field but also by the frequency of polarity changes. The ME3840B expertly differentiates between the following commonly encountered frequencies and frequency bands:

  • 5 Hz to 100 kHz: Ideal for general surveying purposes
  • 16.7 Hz: Specific to overhead railway wires in Germany, France, Norway, Austria, Sweden, and Switzerland
  • 50 Hz to 100 kHz: Addresses the general power grid and associated harmonics
  • 2 kHz to 100 kHz: Targets "artificial harmonics" above 2 kHz, commonly found in AC adapters, energy-saving bulbs, and TV sets, following the Swedish TCO guideline's Band 2. A factor of 10 lower safe limits are recommended for this range.

Advanced Features for Precise EMF Measurements and Dirty Electricity Detection

In addition to the capabilities of the ME3830B, the ME3840B is equipped with a switchable internal filter module similar to those found in professional-grade devices. This feature enables users to numerically differentiate between various EMF pollution sources, such as Dirty Power, mains supply, and traction power. The ME3840B is essential for adhering to the stringent Building Biology recommendations, particularly for the frequency range from 2 kHz and above, also known as "Dirty Power."

State-of-the-Art Functions for Superior EMF Protection

The ME3840B measures magnetic and electric fields using scientifically validated methodologies, delivering exceptional sensitivity (display resolution: 1 nT or 1 V/m). The "Geiger counter effect" aids in pinpointing areas with elevated LF stress. Comprehensive measurement instructions are included, empowering users to conduct accurate EMF measurements without requiring prior technical expertise. This device detects concealed sources of LF pollution. Its accompanying manual offers recommendations for limiting values per the standard of building biology SBM, allowing users to assess their personal EMF exposure levels accurately. Gigahertz Solution devices have been granted numerous patents, have demonstrated their reliability in thousands of applications, and consistently outperformed competitors in their price range.

Take Control of Your EMF Exposure with the ME3840B

Upgrade your EMF protection with the ME3840B, featuring advanced frequency analysis for superior dirty electricity detection. Order your state-of-the-art EMF meter today and begin monitoring the electrosmog emissions from your electrical wiring and appliances with unparalleled precision and professional-grade measurement capabilities.

Features

  • Measures both electric and magnetic ELF fields
  • Easy to operate with no technical experience required
  • Reading shows the total pollution without any calculation required
  • Values are reliably displayed directly in units corresponding to the building biology standards
  • Electric field strength from 1 to 1999 V/m (against ground potential), and the magnetic flux density from 1 to 1999 nT (0.01mG to 20mG)
  • An acoustic signal proportional to the field strength with "Geiger-counter-effect" helps in identifying regions with more exposure
  • Internal filter module for frequency differentation

Benefits

  • Understand your environment through dual measurements of electric and magnetic ELF fields
  • Effortlessly assess EMF levels, no technical knowledge necessary
  • Immediate insights into pollution levels, no calculations required
  • Measurements adhere to building biology standards for a safer space
  • Wide measurement range detects subtle electromagnetic variations effectively
  • Audible signal pinpoints high EMF areas, aiding targeted exposure reduction

What's Included

  • Factory calibrated ME3030B ELF EMF meter
  • Battery
  • Earthing lead
  • Instructions with building biology recommendations

    Specs

    Item weight: 0.40 kg
    Frequency range:

    5 Hz - 100 KHz (compensated, better than -2 dB).
    Internal switchable frequency filter: 16 Hz bandpass, 50 Hz highpass, 2 kHz highpass for building biology analysis to identify railroad and mains current as well as higher frequency harmonics.

    Scope of delivery:

    Measuring device
    Grounding cable
    Alkaline manganese battery
    Detailed instruction manual with neutral Background information

    Measurement range:

    Magnetic flux density (one-dimensional): 1 - 1999 nT
    Electric field strength: 1 - 1999 V/m

    Precision:

    +/- 2 %, +/- 14 digits @ 50/60 Hz

    Sensor:

    E-field sensor for electric LF alternating fields
    H-field sensor for magnetic LF alternating fields (one-dimensional)

    Audio analysis:

    Sound signal proportional to field strength (with "Geiger counter effect", switchable)

    Signal rating:

    RMS

    Power supply:

    9-volt E-block alkaline manganese battery (included), average operating time: 24 to 36 hours (depending on operating mode)
    Low-Batt. indicator
    Auto power-off function

    Warranty:

    2 years

    NOTE

    The meters supplied by Anti-Radiation are manufacturer calibrated and are suitable for general use. Customers who wish to use our meters for certain types of formal testing, for example occupational EMF assessment to meet the needs of the UK HSE or EU EMF Directives, will most likely need to arrange for certification of individual units at an approved calibration facility. This type of certification is a common requirement  for many types of test equipment, not just EMF meters.


    • This meter is for Power Frequency (ELF) EMFs - please see my other items for RF meters suitable for measuring EMFs from mobile phones etc.
    • The measurement range of this meter may be exceeded (without damage) directly underneath 275kv and 400kv overhead lines.

    Manual

    ME3030B Manual

    Returns

    You can request to return your item within fourteen days of delivery and return it to us within sixteen days after your request. The customer is responsible for the item's return shipping cost. Items must be in new, sellable condition and with all the original packaging. 

    To initiate a return, please email info@anti-radiation.co.uk. We will provide you with an address to send your return to. The customer must notify Anti-radiation of any damage within the first two days of delivery. If you find any damaged goods within this period, please inform us. We recommend using a trackable shipping service to ensure the safe return of your item. 

    Warranty

    Gigahertz offer a 2 year warranty on all meters. This warranty extends only to the purchaser and terminates upon ownership transfer. It does not extend to commercial or institutional use or installation.

    This warranty is void if the device is subject to alteration, misuse, abuse, accident, natural disaster or non-factory authorised modification or repair. This warranty is also void if the device has been operated or maintained in deviation from the published instructions. The guarantee extends only to manufacturing defects and does not cover any damages resulting from the mishandling of the product by the owner. This warranty does not cover any normal wear and tear due to usage. 

    Customer Reviews

    Be the first to write a review
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    }